Shelter configurator rules: capacity, fit checks and combinations for cycle, bin and waiting shelters
How a shelter configurator counts bikes, bins and seats, checks the fit under the roof and fixes it in one click: formulas, example values and rules.
Short answer: a shelter configurator needs three building blocks: a capacity formula per use (bikes, bins, seats, people), fit checks that test the contents against roof depth and clear height, and combination rules for roof form, roofing and mounting. Our example configurator shows all three with example values and offers a one-click fix for every red check.
What are the inputs?
The example configurator stores everything in whole millimetres. Whether the user sees metres or feet and inches is a display setting only; it never changes the stored values.
| Input | Example values | Effect |
|---|---|---|
| Use | Cycle, waiting, smoking, bin store | Loads its own starting values and remembers the last choices made for each use |
| Mounting | Freestanding, back-to-back, wall-mounted | Back-to-back doubles the depth and the bike sides; not offered for bin stores |
| Length | 1 to 8 bays of 2.00 m, plus a 150 mm roof overhang at each end | Drives capacity and roof area |
| Depth, clear height | 1.20 to 3.50 m and 2.00 to 3.20 m in 100 mm steps | The basis of every fit check |
| Roof | Mono-pitch, curved, pitched (ridge in the middle) or flat; clear or opal polycarbonate, steel sheet, green roof | The profile drives posts, rafters, roofing, panels and checks |
| Contents | Sheffield stands, semi-vertical or two-tier racks; 240 l, 360 l or 1100 l bins with or without doors; bench or leaning rail | Spacing, space needed and capacity |
How is capacity calculated?
Each use has its own formula. All values are example values of a fictional product:
- Bikes = floor(2,000 mm ÷ rack pitch) × bikes per position × bays × sides. Sheffield stands sit at 1,000 mm with 2 bikes each; semi-vertical and two-tier racks at 400 mm with 1 and 2 bikes. That is 4, 5 or 10 bikes per bay; three bays give 12, 15 or 30, and back-to-back doubles it.
- Bins = floor(1,900 mm ÷ (bin width + 30 mm)) per bay: 3 × 240 l, 2 × 360 l or 1 × 1100 l per bay.
- Waiting = roof area ÷ 0.5 m² per person; smoking uses 1 m² per person. A waiting shelter of 2 bays and 1.60 m depth has (4.00 + 0.30) × 1.60 = 6.88 m² of roof, which gives 13 people.
- Seats = floor((length − 0.10 − 1.30 − 0.15 m) ÷ 0.60 m), where 1.30 m is a free space beside the bench. With 2 bays that leaves a 2.45 m bench and 4 seats.
We recalculated the formulas by hand, and the model draws exactly as many stands, bikes and bins as the readout states. In a real project, your rack pitches, bin sizes and space-per-person assumptions go here.
Which fit checks exist, and how are they fixed?
A check turns red when the contents do not fit under the roof. "Make it fit" then sets the value that satisfies it. In the example this does not block the user: they see the reason and decide.
| Check | Example rule | Tested case |
|---|---|---|
| Bikes under the roof | The depth a parked bike takes from the back panel line must stay under the roof | 1.80 m depth goes red; the fix sets 2.30 m |
| Two-tier height | Clear height at least 2.70 m | 2.20 m goes red; the fix sets 2.70 m |
| Bin depth | Inner depth at least bin depth + 150 mm | 1100 l at 1.20 m goes red; the fix sets 1.60 m |
| Open lid | An open lid must fit under the roof | 1100 l at 2.10 m goes red; the fix sets 2.30 m |
| Space beside the bench | 1.30 × 0.90 m kept free for a wheelchair or pushchair | 1 bay goes red; the fix sets 2 bays |
| Open share of a smoking shelter | At least 50 % of the perimeter open | With both end panels it goes red; the fix removes the side panels |
There are also notes without a fix: a 2.00 m access zone in front of two-tier racks and the swing area of bin store doors, both drawn on the ground. All of these rules and values are fictional examples. The bench space and the open share are not legal advice; which requirements a project must meet is for the manufacturer, the designer and the client to decide.
Which combination rules apply?
- Green roof only on flat or mono-pitch roofs. Switch to a curved or pitched roof and the roofing becomes steel sheet, with a message. Choose flat or mono-pitch again and the green roof comes back. A note on the green roof says that loads and approval sit with the manufacturer.
- Post rows in the model (example rule). For a freestanding mono-pitch or flat roof up to 2.50 m deep, the model draws back posts only. Beyond that depth, with curved and pitched roofs, and for bin stores with doors, a front row of posts is added. This is a fictional example value for the picture, not a design; the structure and post layout are for the manufacturer and the structural engineer to set.
- No back panel when wall-mounted. The building wall takes that role; back-to-back, the back panel becomes a centre wall.
Rules like these keep out combinations you do not supply and explain why, which is the core of any rules-based configurator.
What comes out at the end?
The review, the enquiry text and the PDF carry the same rows: use, mounting, size, clear height, roof, walls, fit-out, colour and capacity. The PDF is one page with two views. In our check the rows were identical in four configurations, metric in German and feet and inches in English.
Example configurator · fictional product
Modular shelter configurator
A modular shelter for bikes, waiting passengers, smokers or bins: choose the use, set bays, depth and height, pick roof, walls and fit-out – with live capacity, fit checks and a PDF enquiry.
Try it in the modular shelter configurator. Who benefits from such a configurator is covered in cycle shelter and street furniture configurators. Data, units, phones and privacy are covered in implementing outdoor structure configurators; the project itself in custom 3D configurator development.
What do your own data replace?
For your range we swap the example tables for yours: bay width and overhangs, standard depths and heights or a fixed size list, roof pitches and radii, racks with pitch and space needs, bin sizes, panels and colour card. Capacity and checks follow automatically. Your own fit rules come from your documents; prices per bay and option and a parts list in the PDF are possible but not built into the demo.
Frequently asked questions
Are the capacity formulas universal?
No. Rack pitches, space per person and bin sizes are example values. Your configurator uses your product data.
Does a red check block the enquiry?
Not in the example. The check states the reason and offers a fix. Whether your configurator accepts red enquiries is your decision.
Can it use fixed sizes instead of free input?
Yes. If you only supply certain lengths and depths, we replace the step values with your size list.
Sources