Technology

Chemical store configurator rules: spill sump, storage places and doors

The rules behind a chemical store configurator: storage places from modules and levels, sump volume against a rule, doors, floors and forklifts.

Short answer: a chemical store configurator works with three rule sets. Storage places: how many places do modules, racking and levels give, and how are they filled? Sump: what volume does the spill sump hold, and what does the manufacturer's rule require? Access: which doors, floors and loading routes suit the type? Our example configurator runs all three with sample values. Which rule applies to your product is your decision.

Chemical & hazmat store configurator – preview of the example configurator
Example configurator · fictional product · example values. Loads only when you click. Open the demo page →

Which inputs does a chemical store have?

The example configurator has six steps from type to enquiry. The inputs and what they drive:

InputExample valuesWhat it drives
TypeFront-access store (a door per module) or walk-in store with an aisleDepths, door position, floor, loading route
Modules1 to 4, each 2,900 mm wideOutside size, storage places, sump area
DepthFront-access 1,700 mm; walk-in 4,000 or 5,000 mmOnly the depths of the chosen type
Storage systemFloor storage (1 level), pallet racking (2 or 3 levels), shelving (3 to 5 levels)Levels, clear height, container types
ContainersIBC 1,000 L, drum 200 L (4 per place), canister 20 L on shelvingLimited by free places
Sump height150, 250 or 350 mmSump volume and floor level
FloorDrive-on with ramp or walk-on with step (walk-in store)Forklift loading only with drive-on
DoorDouble swing door, sliding door, roller shutterSliding door only for walk-in with 2+ modules

All sizes and values are sample values of a fictional product.

How are storage places counted and filled?

Each module has two places per level in the example, so a three-module store with two-level pallet racking has twelve places. IBCs take places first, on the floor level from left to right, then the next level; drums follow in groups of four. If a buyer asks for more containers than there are free places, the steppers stop at the last free one. With shelving there are no IBC or drum steppers; the configurator counts canisters per level instead.

Real ranges often have places of different sizes or fixed loading plans per model. In that case we swap the grid for your tables. The principle stays the same: the buyer enters content and sees where it goes.

How is the sump checked against a rule?

The configurator calculates two figures and compares them:

  • Sump volume (example) = inside width × inside depth × sump height × 0.9 (usable share), rounded down to 10 litres.
  • Volume required (example rule) = the larger of 110 % of the largest container and 20 % of the total, rounded up to 10 litres.

Worked example with the demo's values: one front-access module, a 250 mm sump, one IBC and four drums. Inside, the module measures 2,760 × 1,560 mm. 2.76 × 1.56 × 0.25 m × 0.9 gives 968.8 litres, rounded down to 960 L. The largest container is the 1,000 L IBC, and 110 % of it is 1,100 L; 20 % of the 1,800 L total would only be 360 L. The example rule therefore asks for 1,100 L, and the store is 140 L short. The check turns red, the cutaway shows the overflow and the shortfall appears in the summary. With two modules and the same sump height the volume is 1,980 L and the check turns green.

What we checked: an independent review recomputed eight configurations outside the demo and all matched. It also caught a rounding error for drums (200 × 1.1 came out just above 220 in floating point), which was fixed before publication.

The 110 % / 20 % rule is an example rule of this demo, not a statement about any regulation. In Germany, for example, section 18 AwSV sets the requirements for retaining substances hazardous to water [1]; what retention volume a particular store needs is for the manufacturer and the operator to assess. In a project we replace the formula and rule with your volume tables or your own rule, or the configurator simply shows the volume you state for each model.

Which rules apply to doors, floors and forklifts?

  • The sliding door is offered only for walk-in stores with at least two modules, because the leaf runs in front of the neighbouring module. Otherwise it is disabled, with a hint.
  • In a walk-in store, forklift loading needs a drive-on floor with a ramp. It is disabled for shelving, for walk-on floors and when every place is used.
  • IBCs on upper racking levels with a walk-on floor raise a check note.
  • Choosing no ventilation raises a note, so the question does not get lost in the enquiry.

The forklift run is a simplified path, not route planning. It shows the buyer what loading looks like for the chosen type and makes the difference between front access and walk-in obvious.

What data would you supply?

For a configurator with your own range we need module widths and depths per series, your racking with levels and place sizes, the containers you allow for, sump heights with volume tables or your rule, doors and floors with their restrictions, equipment options and colours. Where a rule only exists in your sales office's heads, we write it down with you as condition, consequence and message.

What comes out at the end?

The review lists type, sizes, places, containers, sump volume against the example rule, door, equipment, colours and the example checks. The enquiry text carries the same rows; the PDF adds a corner view and the sump cutaway. In testing, all 15 summary rows appeared word for word in the enquiry text.

Example configurator · fictional product

Chemical & hazmat store configurator

Plan a steel chemical store: choose front access or walk-in, modules, storage system and door type, place IBCs and drums – with a live sump readout against an example rule, a fill animation, forklift loading and a PDF enquiry.

Prefab process cells · Dimensions and sizes · Colours · Materials and finishes

Try it in the chemical store configurator. Who such a configurator is for is covered in chemical store configurator software, and the technical build (geometry, animation, phones) in implementing configurators for stores, booths and enclosures. For a project of your own, see custom 3D configurator development.

Frequently asked questions

Is the 110 % / 20 % rule a regulation?

No. It is an example rule in this demo. In a project, the rule or table you specify applies.

Can it use fixed volume tables instead of a formula?

Yes. A table per model and sump height is easier to maintain than a formula and reproduces your data sheet exactly.

What happens if a buyer enters more containers than fit?

The steppers stop at the last free place, so the buyer can see that another module or level is needed.

Sources

  1. Federal Ministry of Justice (Germany): section 18 AwSV, requirements for retaining substances hazardous to water, read 14 November 2026: https://www.gesetze-im-internet.de/awsv/__18.html
  2. Modelwright library, chemical and hazmat store configurator, "Live in this demo" list, read 14 November 2026: modelwright.de/en/library/chemical-store-configurator/