Headroom, side room and track type: how a door configurator checks the fit
How a door configurator turns headroom, side room and depth into rules, suggests a track type that fits and handles exclusions. Worked example.
Short answer: the configurator calculates the space each combination of door type, track type, application and operator needs, and compares it with what the buyer measured on site. The rules are a small table of base values and additions. When the check fails, the configurator states the shortfall in millimetres and looks for a track type or door type that fits.
Which inputs does a fit check need?
Three measurements are enough to start: the clear opening (width and height), the headroom available from the top of the opening to the ceiling or the nearest obstruction, and the side room available on each side up to a wall, column or side door. Everything else is derived: headroom needed, side room needed left and right, how far the hardware reaches into the room, and the clear passage once the door is open.
Keep a clear line between what the buyer enters and what you know. Anything measured on site must be enterable, with plus and minus buttons and as a typed number. Anything that is your engineering knowledge belongs in the rule table and is never asked.
The rule table: base value plus additions
In our sectional and roller door example configurator, every installation value sits in one data file, split into domestic garage hardware and industrial or commercial hardware. The figures below are example values for a fictional product, not manufacturer data:
| Track type (sectional door) | Headroom needed, domestic | Headroom needed, industrial |
|---|---|---|
| Standard lift | 330 mm | 450 mm |
| Low headroom | 120 mm | 250 mm |
| High lift | standard + at least 500 mm | standard + at least 500 mm |
| Vertical lift | opening height + 400 mm | opening height + 500 mm |
Additions sit on top. In the example, a domestic door with a ceiling-mounted operator needs 30 mm more headroom and more depth. On an industrial door a shaft-mounted operator on the right adds 250 mm of side room on that side, a hand chain 150 mm. Roller shutters have no track type: their headroom comes from the coil diameter, which grows with height and width and is larger for insulated slats. A high-speed door needs room for its head box.
The structure matters more than the numbers. A new range becomes new rows in the table, not new code, and the same table doubles as a test plan.
A suggestion instead of an error
A red check on its own leaves the buyer stuck. The example configurator therefore looks for an alternative in a fixed order:
- If high lift or vertical lift is selected and standard lift fits the headroom, suggest standard lift.
- Otherwise suggest low headroom, if that fits.
- If a roller shutter or high-speed door does not fit, suggest a sectional door with standard or low-headroom tracks.
- If nothing fits, say so and ask the buyer to check the headroom on site.
A worked example from the demo: industrial hall, sectional door, standard lift, 300 mm of headroom available. 450 mm is needed, so the check is 150 mm short and the clash zone is shown in red in the section view. Low headroom needs only 250 mm; the configurator offers it, one click applies it, and the check turns green.
Tested: in an independent QA round, the fit arithmetic matched in 11 of 11 recomputed configurations, and the suggestion was correct in 9 of 9 test cases. After Apply the check was green every time, and where no track type fits, no suggestion appears.
Exclusions and dependencies
Besides space, some rules lock or unlock options. In the example:
- A wicket door only on sectional doors from 2.50 m wide and 2.20 m high.
- Photo eye, closing-edge strip, traffic lights and motion detector only with an electric operator; bollards always.
- The high-speed door always has an electric operator and is not offered for domestic garages.
- Track types apply to sectional doors only; when the door type changes, values are adjusted to that type and sizes are brought into its range, with a short message.
- Size ranges per application and door type, for example a clear width of 2.00 to 8.00 m for an industrial hall, in 250 mm steps with the plus and minus buttons.
Accessories appear in the model and as icons. The demo explicitly makes no statement on compliance with standards; the manufacturer specifies the equipment.
Clear passage with a vehicle
The clear opening is not the clear passage. Depending on the track type, the open door takes some height. The example configurator works out the passage with the door open and compares it with an example forklift, high-roof van or car. With less than 20 cm to spare in height or 25 cm on each side the result is "tight", otherwise "fits" or "does not fit" (example rule). On request the door opens and the vehicle drives through.
From result to enquiry
All values and check results go into a review. From it come an enquiry text to copy and a two-page PDF with an outside view and the section; every review row and every check title also appears in the PDF. Nothing is sent from the demo: the text and PDF are created in the browser. Insulation and wind figures are shown as example values, not ratings.
Example configurator · fictional product
Sectional & roller door configurator
Plan an industrial or garage door: enter headroom and side room and see in the building section at once whether tracks, barrel or head box fit.
What this means for your range
For a real range we replace the example values with your installation dimensions per range and hardware type: headroom, side room and depth per track type, operator additions, size ranges and your exclusions. How geometry, opening paths and the section view are built is covered in implementation decisions for door, gate and window configurators. The business case for sales and dealers is in sectional and roller door configurator software, and our service is described on custom 3D configurator development.
Frequently asked questions
Can a configurator replace the site survey?
No. It checks plausibility with the measurements entered and your rules. The survey on site is still needed.
Who maintains the installation values?
They are stored as data, separate from the 3D model. We make changes as part of care; a self-service editor is not standard.
Sources
- Example configurator: the data file and QA log of the sectional and roller door demo (Modelwright, 14 November 2026); features as listed on the library page