Technology

Mobile stage configurator rules: set-up, road height, footprint, stairs and ramp

The rules a stage trailer configurator needs: stage size from the build, road height, footprint with working space, stairs, ramp and roof cover.

Short answer: a mobile stage configurator derives everything from a few base dimensions: body length, body width and deck wings give the stage deck; deck and wall height give the road height; stage, stairs, ramp and PA wings give the footprint. On top come rules that prevent invalid combinations, such as a ramp on a deck that is too high. Our example configurator implements this with sample values; the numbers below come from the demo and apply only to it.

Mobile stage trailer configurator – preview of the example configurator
Example configurator · fictional product · example values. Loads only when you click. Open the demo page →

Which parameters does a mobile stage have?

In the mobile stage trailer configurator these are the inputs:

ParameterExample valuesAffects
Size classS (7.0 m body), M (9.0 m), L (11.0 m)stage width, road length, axles
Deck wingsfront only or front + rearstage depth, footprint
Deck height in show mode1.10, 1.30 or 1.50 mstairs, ramp
Roofflat or arched, clear height 4.0, 4.5 or 5.0 mroad height, overall height
Trusses and lightsnone, front, front + middle; lights on or offlights only with a truss
Wallsrear and side walls open, mesh scrim or solidlook
Access1 stair, 2 stairs, stair + ramp; handrails; skirtingfootprint, ramp rule
PA and bannersnone, PA wings, wings + towers; blank banner panelsfootprint, overall height
Site12–40 × 10–30 msite check

All values are sample values of a fictional product. In the demo they sit in a separate data file so that a manufacturer could replace them with its own series.

How does the stage size follow from the build?

The demo follows a design in which the trailer's side walls fold down into deck wings and their upper part opens as roof wings. The depth of a deck wing therefore follows from the cross-section: side wall height plus roof thickness minus roof wing plus wing thickness, 2.00 m in the example. Stage depth is the 2.50 m body width plus one or two wings. For size M with wings front and rear that makes 9.00 × 6.50 m, or 58.5 m² of deck.

The advantage of deriving it: if a manufacturer changes a base dimension, stage size, model and enquiry stay consistent without anyone maintaining a second table.

How is road height checked?

In road mode the deck sits at 1.10 m. Add the 2.60 m side wall and the 0.18 m roof, plus another 0.10 m for the arched roof. That gives 3.88 m with the flat roof and 3.98 m with the arched roof. The check compares this with an example limit of 4.00 m and shows green or red. Road length follows from body and drawbar. Which limits actually apply on the road and which approval a trailer needs is for the manufacturer to settle; the demo says nothing about it.

How is the footprint calculated?

The show-mode footprint is more than the deck. To the sides come the drawbar, stairs, ramp or PA wings, whichever reaches further; to the front and rear, the deck wings or the extended outriggers. Around that area the demo adds a working margin of 1.00 m on every side and compares the result with the site the organiser enters.

With the demo's defaults (size M, wings front and rear, 1.30 m deck, two stairs and PA wings) the calculation in the code gives about 14.8 × 8.5 m including the working margin. The default site of 22 × 16 m is large enough; on the smallest site of 12 × 10 m the check turns red. The sentence in the review names site, space needed and working margin so the organiser sees how much is missing.

Which rules apply to stairs and the ramp?

  • Stairs: the number of risers follows from deck height and an example maximum rise of 0.20 m. At 1.30 m that is 7 risers of about 0.186 m each and a going of 6 × 0.27 = 1.62 m. The check states both values.
  • Ramp: the example rule is a slope of 1 in 4 and only up to a 1.30 m deck. At 1.30 m the ramp is 5.20 m long. Pick a 1.50 m deck afterwards and the configurator switches to two stairs and says so: "A ramp does not suit a 1.50 m deck: switched to 2 stairs." The ramp button is then disabled.
  • Lights: fixtures hang on the truss. Without a truss the lights stay off and a note says a truss is needed.

Which slopes, rises and handrails apply to your stages is up to you. The configurator implements your values and labels them as your rules.

What the roof check shows

An info line states how much of the stage depth the roof covers: in the demo, the body width plus two roof wings, 2.50 + 2 × 0.90 = 4.30 m. With a 6.50 m deep stage, about 1.10 m at the front stays uncovered. For organisers that is a practical question, for example where instruments can stand in rain. Each review also ends with the note that loads, wind values and stability are set only by the manufacturer.

What data do you provide?

For a configurator with your stages we need the cross-section and base dimensions per series, your deck and roof heights, the set-up sequence in phases, your options for walls, access, lighting and PA, your values for stairs, ramp and working margin, and your limits for road dimensions.

What comes out at the end?

The review shows every choice, the stage deck, deck area, road size and the checks. The last step asks for name, company, email, phone, type of use and quantity up to "fleet". Enquiry text and PDF hold the same lines; the PDF has two pages with show and road views. In the demo your entries are not sent; text and PDF are created in the browser. How animation, checks and PDF are built technically is covered in building configurators for trade fair and event structures.

Example configurator · fictional product

Mobile stage trailer configurator

Configure a mobile stage trailer: choose the size class, deck wings, deck height, roof, walls, stairs, PA wings and banners – then scrub from the closed trailer in road mode to the finished stage, with a site footprint check and a PDF enquiry.

Exhibition & event structures · Dimensions and sizes · Colours · Options, modules and accessories

Who such a configurator is for is covered in mobile stage trailer configurator for manufacturers. For the project process, see 3D configurator development.

Send us the cross-section and set-up sequence of your stages.

Frequently asked questions

Are the demo's ramp slope and road height generally valid?

No. They are sample values. You set the values that apply to your stages and markets.

Our stage unfolds differently. Does this still work?

Yes. Design and set-up phases are modelled for your product. The logic stays the same: base dimensions in; stage size, road size and footprint out.

Can it show the pack-down?

Yes. The set-up slider in the demo plays both ways.