Staircase configurator logic: rise, going, step length and headroom
How a staircase configurator turns floor height and space into risers, run and headroom, with example values, suggestions and rules you can replace.
Short answer: a staircase configurator calculates in a fixed order. The floor-to-floor height gives the number of risers, the rise gives the going, and both give the run and the pitch. For L and U stairs the treads are split over two flights. Then it checks length and headroom and makes suggestions. In our example configurator every range is an example value; in a project your own planning values and the applicable building rules take their place.
Which inputs does the configurator need?
Five sizes describe the site. In the example configurator they have these example ranges:
| Input | Meaning | Example range in the demo |
|---|---|---|
| Floor-to-floor height | finished floor below to finished floor above | 2,400–3,600 mm, 50 mm steps, typed to the millimetre |
| Floor thickness at the opening | build-up of the upper floor; sets the underside for the headroom | 160–400 mm |
| Stair width | width of the flight | 800, 900, 1,000, 1,100 or 1,200 mm |
| Available length along the wall | space for the stair | 2,000–9,000 mm |
| Length of the floor opening | opening in the upper floor | 1,000–7,000 mm, automatic or manual |
Shape (straight, L, U), turn with a landing or winders, and turn direction left or right complete the inputs. Invalid entries get a red message and are not taken over; values outside the range are set to the limit, and the demo says so.
How are risers and going calculated?
- Number of risers. Automatically the demo picks the count whose rise is closest to 175 mm. By hand it can only be changed as far as the rise stays between 150 and 200 mm.
- Rise. r = floor-to-floor height ÷ number of risers.
- Going. Automatically g = 630 mm − 2r, rounded to 5 mm; by hand 220–340 mm in 5 mm steps.
- Treads and run. There is one tread fewer than risers, because the upper floor is the last step. Run = treads × g; the pitch follows from r and g.
A worked example with the demo's logic: at 3.00 m floor-to-floor height the result is 17 risers of about 176.5 mm, a 275 mm going, 16 treads and a 4.40 m run. The step length 2r + g is 628 mm and the pitch 32.7°. At 2.80 m it is 16 risers of 175 mm, a 280 mm going and a step length of exactly 630 mm.
The demo shows this calculation live, line by line, and rebuilds the treads in the model at once. Buyers can see why 5 cm more floor height can mean one more step.
Which example ranges does the check use?
The demo compares three values with example ranges and shows them as a note, not as pass or fail:
- Step length 2r + g: example range 590–650 mm, shown as a band; the automatic calculation aims at 630 mm.
- Rise: example range 160–190 mm.
- Going: example range 250–310 mm.
A value outside its range gets an amber note instead of a tick in the check list; for the step length the marker on the band also turns red. Below the checks sits the sentence that this is an example calculation and that the manufacturer and the applicable building rules decide. Which values apply to a building depends on its use and location; agree them with the designer and check the local rules. In a project your step tables and your preferred step rule sit in this place.
How are L and U stairs split?
For L and U stairs the demo divides the treads between two flights and a turn. In the example the turn counts as one step for a landing, as three winders for an L stair and as six for a U stair. The lower flight gets half of the remaining treads, rounded down, and the upper flight the rest. A U stair has a 150 mm gap between the flights.
The footprint follows from that: a straight stair needs treads × g along the wall, an L stair the upper flight plus one stair width along the wall and the lower flight plus one stair width into the room, a U stair the longer flight plus one stair width along the wall and two widths plus the gap into the room. At 2.80 m floor height and 1.00 m width that is 4.20 m for the straight stair and 2.96 m along the wall for an L or U stair with a landing.
If the straight stair is longer than the available space, the length check turns red and the demo suggests an L or U stair if one of them fits; otherwise it asks you to check the length or floor height on site. With winders the going is measured on the walking line; the demo notes that it is much smaller on the narrow side.
How does the configurator check headroom?
Headroom is easy to overlook when planning. The demo works like this:
- The walking line in the middle of the flights (at half width over winders) is sampled every 40 mm.
- Where the upper floor is above the line, the vertical distance from the line of the tread nosings to the underside of the floor is measured. The underside sits at floor-to-floor height minus floor thickness.
- The smallest distance is compared with the example value of 2,000 mm. If it falls short, the readout turns red. In the headroom view the envelope in the model turns red there and a marker shows the conflict point on the edge of the floor; during the walk up the camera ducks at that point.
- The suggestion names the shortest opening length that works in the example, plus 100 mm. In automatic mode the demo sets that length itself; with the default set-up that is 3.75 m.
In the example the opening is 50 mm wider than the stair's footprint. Headroom is checked along the walking line only, not across the full width; the demo's library page says so too.
Which combination rules are there?
- Cantilevered treads are available for a straight stair along the wall only. Switching to an L or U stair sets the construction to closed stringer and shows a message.
- Cantilevered treads always have open risers in the example.
- The folded steel plate always has closed risers; the wood colour for the steelwork is not offered there and is replaced by black.
Every range has rules like these. How we build rules, tables and geometry for stairs is covered in Building a 3D configurator for stairs and balconies.
What is in the enquiry?
The review lists shape, turn, floor height, floor thickness, stair width, steps, step length, pitch, footprint, available length, floor opening, smallest headroom, construction, risers, tread material, balustrade, wall side, handrail and colour, plus all checks. Contact details, project type (private house, refurbishment, office or commercial) and supply with or without installation are added. The enquiry text can be copied, and the PDF holds a 3/4 and a side view. Text and PDF are created in the browser; the inputs are not sent.
Example configurator · fictional product
Staircase configurator: straight, L and U stairs
Plan a straight, L or U stair: enter the floor height, see rise, going and step length live as an example calculation, check the headroom at the floor opening and walk up the stair in 3D.
Who such a configurator suits and what sales needs from it is covered in Staircase configurator for straight, L and U stairs. The project process is described in 3D configurator development.
Send us your step tables and planning values – we show how your configurator calculates with them.
Frequently asked questions
Can we use our own step tables instead of the formula?
Yes. The example going formula and the example ranges live in a data file. In a project your tables and planning values replace them, and the interface labels them as your values.
Is the calculation a building-regulation check?
No. The demo says in the interface, the enquiry text and the PDF that it is an example calculation. Your own design, the designer on site and the applicable rules decide.
Why is headroom checked on the walking line only?
That is how the example rule is built, and the demo's library page says so. If you need a check across the full width or for special opening shapes, the rule is extended in the project.
Sources
- Demo features: "Live in this demo" list on the staircase configurator library page, read 15 November 2026: modelwright.de/en/library/staircase-configurator/
- Input ranges, calculation rules, flight split, headroom check and combination rules: demo source code (data.js, app.js) and schema notes; worked examples recomputed with the same formula on 15 November 2026.