Technology

Washroom cubicle configurator rules: lengths, clearances and locker grids

The rules a toilet cubicle and locker configurator needs: run length, door swing at the pan, corridor width, turning circle, locker grid and bench gap.

Short answer: a configurator for toilet cubicles and lockers needs three groups of rules. Lengths: how cubicles, end cubicle, urinals and vanity add up to an overall length. Clearances: whether the door clears the pan, the corridor is wide enough, the end cubicle has its turning circle and a locker door has room in front of the bench. Grids: how banks, columns and tiers become a locker count. Each rule can be written as a formula and a limit. Our example configurator shows all three with example values.

Washroom cubicle & locker configurator – preview of the example configurator
Example configurator · fictional product · example values. Loads only when you click. Open the demo page →

What are the inputs for a washroom with a cubicle run?

The example configurator has six steps: product, dimensions, options, materials, review and enquiry. The main washroom inputs are:

InputRange in the exampleAffects
Cubicles in the run1 to 8Run length, number of doors
Cubicle width (centres)800 to 1,200 mm in 50 mm stepsDoor width, run length
Cubicle depth1,400 to 2,000 mmSpace in front of the pan, corridor
Room depth (wall to wall)2,400 to 5,000 mm in 100 mm stepsCorridor, outward door check
HeightStandard on legs (about 2,000 mm) or full height (about 2,400 mm)View, row end
End cubicleNone, ambulant, or large end cubicle (1,500–2,400 × 1,900–2,600 mm)Door direction, turning-circle check
Duct wall (IPS)Off, half height with shelf, full height with access panelsDistance of the run from the wall
Urinals, vanity0 to 5 urinals, 0 to 4 basinsOverall length

All values are example values for a fictional product. In a project, your size tables apply.

How is the overall length built up?

The room is laid out from left to right. In the example:

  • Standard cubicles: count × width.
  • Ambulant cubicle: 1,000 mm wide and at least 1,700 mm deep; large end cubicle: width and depth chosen within the range.
  • Urinals: 450 mm from the run, then 700 mm per urinal; the duct wall ends 150 mm beyond.
  • Vanity: 350 mm gap, then 650 mm per basin plus 150 mm.

Worked example with the default values: 3 cubicles × 900 mm plus a 1,000 mm ambulant cubicle give a 3,700 mm run. Two urinals span 4,150 to 5,550 mm, the duct wall ends at 5,700 mm, and a two-basin vanity spans 6,050 to 7,500 mm. The plan's dimension chain reads 900 + 900 + 900 + 1,000 | 1,400 | 1,450, total 7,500 mm. QA recalculated these values by hand.

Which clearances does it check?

In the washroom there are up to four checks. Each shows "fits" or "check" in the review; the 3D model colours the checked areas, and the plan marks the door swings and the turning circle:

CheckExample ruleDefault values
Inward door at the panFree depth in front of the pan (cubicle depth − 540 mm) minus door width (cubicle width − 260 mm) ≥ 60 mm960 − 640 = 320 mm: fits
Corridor in front of the runRoom depth − duct void − deepest cubicle ≥ 1,200 mm3,400 − 1,900 = 1,500 mm: fits
Outward door of the end cubicleCorridor in front of it ≥ door width + 300 mm800 + 300 = 1,100 ≤ 1,500: fits
Turning circle in the large end cubicleSmaller of width and (depth − 540 mm), minus twice the panel thickness, ≥ Ø 1,500 mmAt 1,700 × 2,200: 1,636 mm: fits

A second QA case shows how the checks interact. With six 950 mm cubicles and a 1,700 × 2,200 mm large end cubicle, only 1,000 mm of corridor remain in front of the end cubicle. The corridor check and the outward door check (900 + 300 = 1,200 mm) turn to "check", while the turning circle fits. The plan shows the specifier that either the room must be deeper or the end cubicle shallower.

Every limit is an example value and is labelled "example value, not guaranteed" in the configurator. Which dimensions apply to your products and to a given project is decided by you as the manufacturer and by the project's designers, not by the configurator.

How are the locker grid and bench handled?

In the changing room, lockers = banks × columns × tiers. The defaults give 2 × 4 × 3 = 24 lockers; the maximum is 4 × 6 × 6 = 144. A bank is columns × column width + 40 mm wide, so four 380 mm columns make 1,560 mm. Column widths (300, 380, 450 mm) and depths (450, 500 mm) are list values, not free inputs.

Two checks belong to a freestanding bench:

  • Locker door and bench: the gap to the bench must be at least the door width (column width − 6 mm). A 400 mm gap in front of a 444 mm door gives "check"; 450 mm gives "fits".
  • Aisle behind the bench: room depth − locker depth − gap − 380 mm bench depth ≥ 900 mm. With the defaults: 3,400 − 1,780 = 1,620 mm, which fits.

Without a freestanding bench, the configurator checks the aisle in front of the lockers against the same example value.

How does it prevent impossible rooms?

Some inputs produce a room that could not be built, such as a 2,600 mm deep end cubicle in a 2,400 mm deep room. In the example, the room depth is therefore raised automatically to at least the deepest front + 600 mm, and the bench gap is capped so that 600 mm remain behind the bench. Both show a notice ("Adjusted to … mm"). Values outside a range are set to the limit with a notice, and numbers typed with thousands separators, such as "3,100", are read correctly.

The difference matters: a red check is information for the conversation, while an automatic adjustment stops an enquiry that could not physically work.

What data do you supply for your rules?

For a configurator with your own systems we need the documents your sales office plans with today: widths and depths per cubicle range, door widths per cubicle width, heights, panel thicknesses per material, your dimensions and notes for ambulant and accessible cubicles, duct wall dimensions, locker grids with column widths, depths and tier heights, bench sizes and the lock options you supply. Where a rule is not written down, we write it with your sales team as a condition, a consequence and a note.

What comes out at the end?

The review shows every choice and every check. The enquiry text and the PDF are built from the same rows; the PDF adds the 3D view and the dimensioned plan. In the demo, text and PDF are created in the browser only; nothing is sent.

Example configurator · fictional product

Washroom cubicle & locker configurator

Plan a washroom or changing room: cubicle row, end cubicle, duct wall, urinals and vanity, or locker banks with benches – with a plan view, a clearance check and a PDF enquiry.

Partitions, guarding & shelving · Dimensions and sizes · Colours · Materials and finishes

Try it in the washroom cubicle and locker configurator. Who this kind of configurator suits is covered in locker and washroom cubicle configurator for manufacturers, and the technical build in building a washroom and locker configurator. For a project, see custom 3D configurator development.

Frequently asked questions

Are the clearance values taken from a standard?

No. They are example values for this demo. In a project, the values you set as the manufacturer apply.

Does a red check block the enquiry?

Not in the demo: the check appears in the enquiry marked "check". Whether your configurator should behave the same way is your decision.

Can it produce a parts list?

The demo counts cubicles, urinals, basins and lockers and states the overall length. A parts list with your part numbers can be set up in a project.