Technology

Cold room configurator rules: panel grid, temperatures and shelving

The rules a cold room configurator needs: sizes on the panel grid, use and ambient temperature, door, cooling unit, shelving with an aisle, and placement.

Short answer: a cold room configurator needs rules in four areas. Size: which widths, depths and heights does the panel grid allow? Temperature: which use and ambient temperature, and what follows for unit and insulation? Fit-out: how much shelving fits, and does an aisle remain? Placement: does the room fit the space? Our example configurator shows these areas with sample values. This guide explains how a manufacturer would write the rules down.

Cold room configurator – preview of the example configurator
Example configurator · fictional product · example values. Loads only when you click. Open the demo page →

Which inputs does a modular cold room have?

InputIn the demoProposed dependency for your range
Width and depthOn a 100 mm gridOnly sizes on your panel grid, with minimum and maximum
HeightTwo heightsYour available heights; room height as a limit
Use and ambient temperatureWith a ΔT checkTemperature range drives panel thickness, floor and unit choice
FloorSelectableDepends on temperature range and use
DoorPosition and hinge sideDoor widths per room size; position in whole panels only
Cooling unitPlug-in units as optionsChoice by volume and temperature range from your table
ShelvingLayout with an aisle checkShelf depth and minimum aisle from your rules
PlacementCheck in the roomClearances to wall and ceiling, delivery route

The "proposed dependency" column describes how we would build the rules for a manufacturer; it does not describe the demo's logic. All demo values are sample values of a fictional product.

How does the panel grid become a rule?

Cold rooms are made from wall, ceiling and floor panels. A buyer types the size they have in mind, say "two metres wide". The configurator should turn that into the next size you can supply and say so, rather than accept a size you do not build. We suggest keeping the grid as a list of panel widths rather than a formula, so that ranges with different corner or filler panels can be modelled too.

Grid and height give inside size, outside size and volume. All three belong on the data sheet, because buyer and contractor think in different terms: the buyer in the room, the contractor in the volume.

How are temperature and surroundings checked?

The demo asks for use and ambient temperature and checks the difference, the ΔT. It is a simple but effective idea: a chiller in a warm room is a different job from the same chiller in a cool cellar. For a manufacturer's range we recommend:

  • the use temperature as a choice from your classes, such as chilled or frozen, rather than a free number;
  • the ambient temperature as a required input with a sensible default;
  • notes according to your rules when the difference points to another panel thickness, a heated floor or a different unit.

All values come from your documents. The configurator does no refrigeration design; it only shows what your tables say for a combination and writes both temperatures onto the data sheet so the contractor can check.

How does shelving with an aisle check work?

The demo lays out shelving in the room and checks that an aisle remains. For your own range we suggest storing shelving systems with depth and levels, allowing shelving only on walls without a door, and checking a minimum aisle from your rules. If the aisle gets too narrow, the configurator names the missing centimetres and suggests a larger room or less shelving. For many buyers this is the moment they realise the room should be one grid step deeper.

How is placement checked?

The demo checks placement in the room. For a manufacturer's range we would include room size, the clearances to walls and ceiling you require for installation and for the unit to breathe, and optionally the delivery route: do the panels get through doors and corridors? The result is a planning aid; your installer checks on site.

Why a data sheet rather than just an enquiry?

With modular cold rooms, the document at the end often matters more than the enquiry itself. Buyers pass it to their contractor, kitchen designer or management, and it has to stand on its own. The demo therefore produces a two-page PDF data sheet. For your range we recommend reusing the layout of your current data sheet, so your sales office does not read two formats, and listing every check with its result, together with a clear note that all values are provisional until the quote.

What data would you supply?

Your panel grid and heights, panel thickness per temperature range, door types and widths, floors, units with their operating ranges, shelving systems with sizes, your clearance rules, colours and finishes, and the layout of your current data sheet. Where your team applies rules from experience only, we write them down together.

What comes out at the end?

The demo produces enquiry text to copy and a two-page PDF data sheet. For a manufacturer project, we suggest the data sheet carries inside and outside sizes, volume, both temperatures with the check result, door, floor, unit, shelving plan and colours, plus a view and a plan.

Example configurator · fictional product

Cold room configurator

Plan a cold room: sizes on a 100 mm grid, use and ambient temperature, door, cooling unit and shelving with an aisle check – with a PDF data sheet.

Prefab process cells · Dimensions and sizes · Colours · Options, modules and accessories

Try it in the cold room configurator. Who it is for is covered in cold room configurator software, and the technical build in implementing configurators for stores, booths and enclosures. For a project, see custom 3D configurator development.

Frequently asked questions

Can buyers type any size?

We recommend letting them type what they have in mind, with the configurator rounding to the next size you supply and saying so.

Can chilled and frozen rooms share one configurator?

Yes, as temperature classes with their own panel thickness, floors and units from your tables.

Can buyers plan several rooms in one enquiry?

Not in the demo. In a project a line-item list is possible if your buyers often order several rooms.

Sources

  1. Modelwright library, cold room configurator, "Live in this demo" list, read 14 November 2026: modelwright.de/en/library/cold-room-configurator/