Spray booth configurator rules: airflow type, booth length and bay fit
The rules a spray booth configurator needs: airflow type, length and vehicle class, a fit check against the bay, options with availability rules.
Short answer: a spray booth configurator needs rules on three levels. Booth: which airflow type, which length, which vehicle class? Bay: does the booth fit in length, width and clear height? Options: which equipment is available with which booth? Our example configurator shows these levels with sample values. This guide explains how to write the rules down for your own range; what the demo itself does is listed on its library page.
Which inputs does a spray booth have?
| Input | In the demo | Proposed dependency for your range |
|---|---|---|
| Model by airflow | Cross-flow, semi-down, tower, side and full downdraft | Sets base construction, outside size and possible options |
| Booth length | Selectable | Lengths per series from your list |
| Vehicle size class | Shown in the work area | Minimum length and working space per class |
| Bay length, width, clear height | Checked against the booth | Outside size plus your clearances to walls and ceiling |
| Options | Extension, drive-thru doors, air make-up heating, control centre, ducting, motor, in-ground pit, with availability rules | Availability per booth, exclusions, required combinations |
| Finish | Galvanised or powder coat | Colours or finishes from your range |
The "proposed dependency" column describes how we would build the rules for a manufacturer; it is not a description of the demo's logic. All demo values are sample values of a fictional product.
How does airflow become a rule?
To the buyer, airflow is a term; to the manufacturer, it is a series with its own sizes, parts and options. In a configurator it should therefore not be one field among many but the first choice, with everything else depending on it. We suggest treating each airflow type as its own model, with a list of permitted lengths, options and messages. When the buyer changes the airflow type, the configurator re-checks every option chosen so far and removes or flags whatever no longer fits, with a short note.
The animated air path in the demo has a different job: it explains. Seeing whether air moves across, at an angle or straight down helps a buyer understand why some booth types raise questions about the floor. It is not a design; air volumes and filter areas are for the manufacturer to set.
How do vehicle class and booth length relate?
The demo places a vehicle size class in the booth's work area, so the buyer can see how much room is left around the vehicle before anyone quotes a number. For a manufacturer's range, we suggest giving each vehicle class a minimum length and working space. If a buyer picks a class too large for the chosen length, the configurator should name the next suitable length or the extension option rather than quietly showing a warning. Shops that paint vans, commercial vehicles or parts as well as cars usually need several classes; name them the way your sales conversations do, not by technical dimensions.
How do you check the booth against the bay?
The demo compares the booth with bay length, width and clear height. For your own range we recommend splitting the check into three parts:
- Outside size: length, width and height of the chosen booth, including options that change it, such as an extension or units on the roof.
- Clearances: the free space you require for installation, service and access, to walls and to the ceiling.
- Access: whether vehicles can reach the booth and, with drive-through doors, whether there is room at both ends.
The result should not just say "fits" or "does not fit" but name the constraint: which direction, by how much, and what would help, such as a shorter booth or another type. Such a check is a planning aid. Whether the building is structurally and legally suitable is for the manufacturer and the operator to establish on site.
How are option rules written?
The demo's options come with availability rules. In a manufacturer project we write each rule as condition, consequence and message, for example:
- Condition: booth type X chosen. Consequence: in-ground pit available. Message: "Requires work in the floor; to be agreed on site."
- Condition: drive-through doors chosen. Consequence: the bay check requires free space at both ends.
- Condition: air make-up heating chosen. Consequence: a control centre becomes required or suggested.
These examples show the form only; they say nothing about your product or any real one. What matters is that every rule has a message that tells the buyer why something is missing or has been added.
What data would you supply?
Your series with airflow type and lengths, outside sizes per length, your clearance rules, the option list with availability and exclusions, the vehicle classes you advise on, finishes and colours, and the fields your sales team wants in an enquiry. A price list helps even if the configurator shows no prices, because it usually shows which options belong together.
What comes out at the end?
The demo produces enquiry text to copy and a PDF. For a manufacturer project we suggest the enquiry carries booth type, length, vehicle class, the bay dimensions entered, the result of the bay check, the options and the finish, plus a view of the booth in the bay.
Example configurator · fictional product
Spray booth planner
Plan a spray booth: five airflow types, length, vehicle size, a bay fit check, options with availability rules and an animated air path – with a PDF enquiry.
Try it in the spray booth planner. Who such a configurator is for is covered in spray booth configurator software; geometry, animation and phones in implementing configurators for stores, booths and enclosures. For a project, see custom 3D configurator development.
Frequently asked questions
Can the bay check suggest a fix?
Yes, if you define the alternatives, such as a shorter length or another booth type. The configurator can then offer them as suggestions.
Does this work in feet and millimetres?
The demo switches between ft and mm. In a project you keep the data in one unit and the display converts.
Does it replace the site survey?
No, it prepares it. Engineering and permits stay with the manufacturer, the operator and the authorities.