Walk-in cooler configurator rules: doors, glass openings and floor plan
The rules a made-to-measure walk-in cooler configurator needs: type, location, sizes, doors and glass openings on any wall, door values, floor.
Short answer: a configurator for made-to-measure walk-ins needs rules for four questions. Type: cooler, freezer or combination, indoor or outdoor? Size: which sizes can be supplied, in which unit? Openings: where may doors and glass openings sit on a wall, and what does that mean for the drawing? Equipment: which floors, ramps and units fit? Our example configurator shows these questions with sample values. This guide explains how a manufacturer would write the rules down.
Which inputs does a made-to-measure walk-in have?
| Input | In the demo | Proposed dependency for your range |
|---|---|---|
| Type | Cooler, freezer or combination | Panel thickness, floor, door types, unit choice |
| Location | Indoor or outdoor | Outdoor: roof, finishes, base |
| Size | Sample sizes or own sizes in ft-in or mm | Grid, minimum and maximum sizes, heights |
| Doors and glass openings | Dragged along any wall in plan or 3D | Minimum distances to corners, joints and each other |
| Door values | Size, hinge, side and offset for a drawing form | Your door sizes and reference points |
| Floor, ramps, unit, accessories | Selectable | Depends on type, use and location |
| Finishes and insulation | Exterior and interior with a palette; insulation with sample values | Your finishes and panel thicknesses |
The "proposed dependency" column describes how we would build the rules for a manufacturer; it does not describe the demo's logic. All demo values are sample values of a fictional product.
How are doors and glass openings controlled?
The signature of this demo is that doors and glass openings are not picked from a list but dragged along the wall, on the plan or directly in the 3D model. For buyers that is the natural way to plan. For the manufacturer it means every position must be checked against rules. For a range, we would propose:
- A minimum distance to the corner, so the frame and wall junction have room.
- A minimum distance between two openings on the same wall.
- Grid or free position: either the opening snaps to panel joints, or it is free and the configurator shows which panels must be adapted.
- Type rules: which doors are allowed for freezers or outdoor units, and whether glass openings are offered there.
If a buyer drags a door into a forbidden zone, it should stop at the nearest allowed position with a short note explaining why.
What belongs in the door values for the drawing?
The demo outputs door size, hinge, side and offset as values a drawing request form asks for. That is the real benefit for sales: a door's position is described without anyone interpreting a sketch. For your range we recommend fixing the reference point, for example "offset from the left outside corner, seen from outside", and using exactly that wording in the enquiry and PDF. With several openings, each should have its own line with wall, type, size, hinge and offset.
How is a combination handled?
In the demo the cooler-freezer combination is its own type. For a manufacturer's range we suggest treating it as two rooms sharing a partition wall, each with its own rules: the partition position in your grid steps; whether the freezer is reached only through the cooler or has its own outside door; floors, door types and units per section from your tables; and separate lines in the enquiry and PDF so each section stays traceable. How your range solves this today decides the rules; the configurator only implements them.
How do you handle feet-inches and millimetres?
The demo takes sizes in ft-in or mm. For makers who supply both systems we suggest keeping all data in one unit and converting only the display. Rounding matters: a size typed in inches should not jump a grid step when shown in millimetres. We agree the rule with you, and the enquiry and PDF show both values.
How are floor, ramps and unit tied in?
The demo offers floor, ramps, refrigeration unit and accessories as options. For a manufacturer we recommend rules such as ramps only at doors that are driven through, certain floors only with certain types, and units by type, volume and location from your table. These rules show the form only; technical values always come from your documents, and design is done by your team or the refrigeration contractor.
What comes out at the end?
The demo ends with a review with checks, enquiry text to copy and a PDF. For a manufacturer project we suggest the enquiry carries type, location, sizes, every opening with its values, equipment, finishes and check notes, plus a floor plan with the openings marked.
Example configurator · fictional product
Walk-in cooler configurator
Plan a walk-in cooler or freezer: size, location, doors and glass openings on any wall, floor, refrigeration unit and finishes – with review checks and a PDF enquiry.
Try it in the walk-in cooler configurator. Who it is for is covered in walk-in cooler configurator software, and the technical build in implementing configurators for stores, booths and enclosures. For a project, see custom 3D configurator development.
Frequently asked questions
How many doors and glass openings are possible?
You decide. The configurator then checks distances and lists each opening as its own line in the enquiry.
Why drag doors in the 3D model?
Because buyers plan the way they see the room. The plan stays alongside for exact values.
What do the check notes show?
In the demo they appear in the review. In a project we write them from your rules, for example about clearances or about doors not offered for a given type.
What changes for outdoor units?
Under your rules, for example roof, finishes and base. The demo offers indoor or outdoor as a choice.
Sources
- Modelwright library, walk-in cooler configurator, "Live in this demo" list, read 14 November 2026: modelwright.de/en/library/walk-in-cooler-configurator/